{"id":3443,"date":"2023-01-05T06:00:46","date_gmt":"2023-01-05T06:00:46","guid":{"rendered":"https:\/\/hemshellwebsite.rnisolutions.in\/?page_id=3443"},"modified":"2023-02-11T09:38:21","modified_gmt":"2023-02-11T09:38:21","slug":"scope-of-calibration","status":"publish","type":"page","link":"https:\/\/www.hemshellservices.com\/index.php\/scope-of-calibration\/","title":{"rendered":"SCOPE OF CALIBRATION"},"content":{"rendered":"<section id=\"bt_bb_section6aea225f129d7\"  class=\"bt_bb_section bt_bb_color_scheme_16 bt_bb_layout_wide bt_bb_vertical_align_top\" ><div class=\"bt_bb_port\"><div class=\"bt_bb_cell\"><div class=\"bt_bb_cell_inner\"><div class=\"bt_bb_row_wrapper bt_bb_row_push_right bt_bb_row_push_left bt_bb_content_wide bt_bb_row_width_boxed_1200\"><div  class=\"bt_bb_row bt_bb_animation_fade_in bt_bb_animation_move_right animate bt_bb_animation_fade_in move_right animate\"  data-bt-override-class=\"{}\"><div  class=\"bt_bb_column col-xl-12 col-xs-12 col-sm-12 col-md-12 col-lg-12 bt_bb_vertical_align_middle bt_bb_align_left bt_bb_padding_20 bt_bb_details-color_white\" style=\"background-color:rgba(255, 255, 255, 1);\" data-width=\"12\" data-bt-override-class=\"{&quot;bt_bb_align_&quot;:{&quot;current_class&quot;:&quot;bt_bb_align_left&quot;,&quot;xl&quot;:&quot;left&quot;}}\"><div class=\"bt_bb_column_content\"><div class=\"bt_bb_column_content_inner\"><div class=\"bt_bb_separator bt_bb_bottom_spacing_large bt_bb_border_style_none bt_bb_border_color_none\"><\/div><header class=\"bt_bb_headline bt_bb_color_scheme_8 bt_bb_dash_none bt_bb_subheadline bt_bb_size_normal bt_bb_align_inherit\" style=\"; --primary-color:#000821; --secondary-color:#ffffff;\" data-bt-override-class=\"{&quot;bt_bb_align_&quot;:{&quot;current_class&quot;:&quot;bt_bb_align_inherit&quot;,&quot;xl&quot;:&quot;inherit&quot;}}\"><h2 class=\"bt_bb_headline_tag\"><span class=\"bt_bb_headline_content\"><span>SCOPE OF CALIBRATION<\/span><\/span><\/h2><div class=\"bt_bb_headline_subheadline\">Mechanical Scope for In-house\/Onsite Calibration<\/div><\/header><div class=\"bt_bb_separator bt_bb_top_spacing_normal bt_bb_bottom_spacing_normal bt_bb_border_style_solid bt_bb_border_color_none\"><\/div><div  class=\"bt_bb_text\" ><table width=\"0\">\n<thead>\n<tr>\n<td><strong>Sr. No.<\/strong><\/td>\n<td><strong>Parameter \/ Measured Quantity<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td><strong>Reference Standards<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>1<\/strong><\/td>\n<td>Primary Force calibration for In-house facility Load Cells, Proving Devices<\/td>\n<td>50N to 5000N<\/td>\n<td>As per IS 4169:2014\/ ISO376<\/td>\n<\/tr>\n<tr>\n<td><strong>2<\/strong><\/td>\n<td>Onsite Force Calibration for Rockwell Hardness Tester<\/td>\n<td>HRC scale<\/td>\n<td>As per IS 1586: 2000<\/td>\n<\/tr>\n<tr>\n<td><strong>3<\/strong><\/td>\n<td>Onsite Force Calibration for UTM\/TTM\/CTM<\/td>\n<td>10N to 300kN<\/td>\n<td>As per IS 1828: Part I : 2005<\/td>\n<\/tr>\n<tr>\n<td><strong>4<\/strong><\/td>\n<td><strong>Vacuum Pressure<\/strong><br \/>\nDigital and Dial Pressure Gauges, Pressure Transmitters<\/td>\n<td>-0.92 bar to -0.1 bar<\/td>\n<td rowspan=\"3\">As per DKD-R 6-1<\/td>\n<\/tr>\n<tr>\n<td><strong>5<\/strong><\/td>\n<td><strong>Pneumatic Pressure<\/strong><br \/>\nDigital and Dial Pressure Gauges, Pressure Transmitters<\/td>\n<td>0 bar to 35 bar<\/td>\n<\/tr>\n<tr>\n<td><strong>6<\/strong><\/td>\n<td><strong>Hydraulic Pressure<\/strong><br \/>\nDigital and Dial Pressure Gauges, Pressure Transmitters<\/td>\n<td>Above 35 bar to 700 bar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><div class=\"bt_bb_separator bt_bb_bottom_spacing_normal bt_bb_border_style_none\"><\/div><div  class=\"bt_bb_text\" ><p><strong>Thermal Scope for In-house\/Onsite Calibration<\/strong><\/p>\n<table width=\"0\">\n<thead>\n<tr>\n<td><strong>Sr. No.<\/strong><\/td>\n<td><strong>Parameter \/ Measured Quantity<\/strong><\/td>\n<td><strong>Range<\/strong><\/td>\n<td width=\"15%\"><strong>Reference Standards<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>1<\/strong><\/td>\n<td>RTDs and All types Thermocouples with Indicator \/ Controller \/ Data logger \/ Recorder, Digital or Glass Thermometer<\/td>\n<td>-22 \u00baC to 155 \u00baC<\/td>\n<td rowspan=\"5\">Direct method and Comparison method with ref. to Guidelines for the International Temperature Scale of 1990 (ITS-90). IS 6274 \u2013 1971 for calibrating Liquid-in Glass Thermometers<\/td>\n<\/tr>\n<tr>\n<td><strong>2<\/strong><\/td>\n<td>RTDs and All types Thermocouples without Indicator \/ Controller \/ Data logger \/ Recorder, Temperature Transmitter,<\/td>\n<td>-22 \u00baC to 155 \u00baC<\/td>\n<\/tr>\n<tr>\n<td><strong>3<\/strong><\/td>\n<td>RTDs and All types Thermocouples with Indicator \/ Controller \/ Data logger \/ Recorder, Temperature Transmitter Digital Thermometer<\/td>\n<td>Above 155 \u00baC To 700 \u00baC<\/td>\n<\/tr>\n<tr>\n<td><strong>4<\/strong><\/td>\n<td>RTDs and All types Thermocouples without Indicator \/ Controller \/ Data logger \/ Recorder, Temperature Transmitter<\/td>\n<td>Above 155 \u00baC To 700 \u00baC<\/td>\n<\/tr>\n<tr>\n<td><strong>5<\/strong><\/td>\n<td>Digital Temperature Bath<\/td>\n<td>-45 \u00baC to 650 \u00baC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><div class=\"bt_bb_separator bt_bb_bottom_spacing_large bt_bb_border_style_none bt_bb_border_color_none\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":2788,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/pages\/3443"}],"collection":[{"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/comments?post=3443"}],"version-history":[{"count":21,"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/pages\/3443\/revisions"}],"predecessor-version":[{"id":3513,"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/pages\/3443\/revisions\/3513"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/media\/2788"}],"wp:attachment":[{"href":"https:\/\/www.hemshellservices.com\/index.php\/wp-json\/wp\/v2\/media?parent=3443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}